Publications
Events

 Submit your event on Detection Methods to be featured.

Submit an Event

Hypoxia Detection Methods


hypoxia markers hypoxia detection in cell lysates single cell detection methods hypoxia 3D culture

How is Hypoxia Detected?

While specialized machinery can directly control and measure levels of oxygen, methods to monitor hypoxia often rely on strategies for the detection of HIF protein expression and other hypoxia markers. Monitoring HIF-alpha levels within cells and tissues provides a measure of the extent of hypoxia and hypoxic gradients. Because HIFs have a notoriously short half-life and are extremely sensitive to oxygen levels, hypoxia is also monitored by key proteins regulated by HIFs (e.g., CA IX, VEGF). Other strategies to detect and monitor hypoxia in vitro include monitoring changes in gene expression via in situ hybridization (ISH) or using fluorescent oxygen-sensitive dyes. Pimonidazole is commonly used to detect hypoxia in vivo.


Hypoxia Markers

Common Hypoxia Marker Antibodies

Target

Signaling

HIF-1 alpha Learn more about Hypoxia Inducible Factors (HIFs)
HIF-2 alpha/EPAS1
Carbonic Anhydrase IX (CA9) Cellular Metabolism
GLUT1
PDK1
VEGF Angiogenesis
BNIP3 Cell Death

Explore More Markers for Hypoxia Signaling


Under normoxic conditions, HIF-alpha subunits are rapidly targeted for degradation by the proteasomal system. Under hypoxia, HIF-alpha subunits are stable resulting in increased protein levels, particularly in the nucleus. Stabilization of HIF-alpha leads to increased expression of downstream proteins, adapting the cells to their hypoxic environment.

Find our top cited HIF-1 alpha antibody NB100-105, with over 900 citations.


ICC image showing CD25 staining in yellow. Simple western lane view showing expression of LAP (TGF-beta 1) by band and simple western badge with blue circle and orange check.

Biological Strategies. Western Blot: Specificity of HIF-2 alpha antibody in MDA-MB-231 cell lysate (overexpression and endogenous samples) using Rabbit Anti-HIF-2 alpha/EPAS1 Polyclonal Antibody (Catalog # NB100-122). The data shows that HIF-2 alpha antibody does not cross-react with HIF-1 alpha overexpression. Additionally, elevated levels of HIF-1 and HIF-2 alpha were detected following incubation of MDA-MB-231 cells under hypoxic conditions. This specificity of this antibody has also been validated with Genetic and Orthogonal Strategies.

Biological Strategies. Immunocytochemistry/Immunofluorescence (ICC/IF): Comparison of HIF-1 alpha expression in Cobalt Chloride (CoCl2) treated (left) and untreated (right)HeLa cells using Rabbit Anti-HIF-1 Alpha Polyclonal Antibody (Catalog # NB100-449). The specificity of this antibody has also been validated with Genetic Strategies.

Carbonic anhydrase IX (CA IX) is a transmembrane glycoprotein induced under hypoxic conditions. Induction of CA IX expression is regulated by HIFs via interaction with an HIF-responsive element (HRE) sequence within the 5’ promoter region of CA IX gene. Because CA IX catalyzes the metabolism of CO2 to carbonic acid, its induction under hypoxic conditions is associated with tumor acidification and poor prognosis in tumors like clear cell renal carcinoma.


Dual ISH-IHC validation of CA IX specificity with left image showing IHC staining (brown) and left image showing ISH staining (red). Circular orthogonal validation strategies badge.

Orthogonal Strategies Validation. Dual RNAscope ISH-IHC: Formalin-fixed paraffin-embedded tissue sections of human stomach were probed for Carbonic Anhydrase IX/CA9 mRNA (ACD RNAScope Probe, catalog # 559348; Fast Red chromogen, ACD catalog # 322750). Adjacent tissue section was processed for immunohistochemistry using Rabbit Anti-Carbonic Anhydrase IX/CA9 (Novus catalog # NB100-417) at 1:1000 dilution with overnight incubation at 4 degrees Celsius followed by incubation with anti-rabbit IgG VisUCyte HRP Polymer Antibody (Novus catalog # VC003) and DAB chromogen (yellow-brown). Tissue was counterstained with hematoxylin (blue). This antibody has been validated with Genetic and Biological Strategies.


Vascular endothelial growth factor (VEGF) is a key regulator of angiogenesis, the process by which new vessels are formed from pre-existent vasculature. VEGF and its receptors VEGF-R1, VEGF-R2 and VEGF-R3 are induced under hypoxia and play critical roles in the formation of new tumor vasculature. Monitoring VEGF/VEGF-R expression serves as a marker for hypoxia.


Histogram plot showing VEGF-R3 staining on the surface of mouse endothelioma cell line in filled histogram compared to isotype control.

Flow Cytometry. Mouse endothelioma cell line bEnd.3 was stained with Goat Anti-Mouse VEGFR3/Flt 4 Polyclonal Antibody (Catalog # AF743, filled histogram) or Goat IgG Isotype Control Antibody (Catalog # AB-108-C, open histogram), followed by PE-conjugated Donkey Anti-Goat IgG Secondary Antibody (Catalog # F0107).


In addition to observed changes in protein expression, hypoxia and the cellular stress response can be monitored by interrogating the function of mitochondria. Mitochondria are an important site of oxygen consumption within the cell, converting glucose into ATP via oxidative phosphorylation (OXPHOS). In addition to the cellular response to hypoxia, mitochondria are critically important in the cellular stress response pathways of autophagy and apoptosis. Bio-Techne has antibodies to critical mitochondrial markers, including ATP5A, NDUFC2 and COX4.

Mitochondrial function can also be assessed with various fluorescent dyes available from Tocris, a Bio-Techne Brand.


Fluorescent Dye

Excitation/Emission (nm)

Function

MitoMark Green

490/516

Green-fluorescent mitochondrial stain, localizes to mitochondria regardless of membrane potential.

MitoMark Red

578/599

Red-fluorescent mitochondrial stain; fluorescence intensity is dependent on mitochondrial membrane potential.
H2DCFDA 490/520 Fluorescent indicator of reactive oxygen species (ROS). Only fluorescent after oxidation.


ICC image of MitoMark Red Stain

Immunocytochemistry/Immunofluorescence (ICC/IF): HeLa cells were stained with MitoMark Red I (Catalog # 6445) diluted in HBSS and applied to live HeLa cells at a concentration of 200 nM. HeLa cells were incubated for 30 minutes at 37°C. 10% formalin was added to the HBSS and MitoMark solution at a ratio of 1:1 for 20 minutes at room temperature. After fixation, the cells were permeabilized. Lastly, mounting media with DAPI (Fluoroshield™ with DAPI from Sigma) was applied to the cells. Images represent a bright-field DIC to see cell boundaries combined with fluorescence.


back to top


Hypoxia Marker Detection in Cell Lysate

Detection and monitoring of hypoxia in cell lysate are important tools to understand the nature of the cellular environment on a population level. Techniques to detect and monitor hypoxia markers in cell lysate include western blot and ELISA.


Application

Advantages

Limitations

Bio-Techne Product Offering

Western Blot

  • Simple data analysis
  • Reagents are well-defined
  • Target validation by molecular weight estimations
  • Reliable detection of phospho-antigens
  • Limited quantitative data
  • Low throughput and time consuming

Primary Antibodies for Hypoxia Markers-Western Blot

Hypoxic Cell Lysates

Antibody Sampler Packs for Hypoxia Markers

Immunoassay (ELISA, Luminex)

  • High throughput
  • Simple data analysis
  • Quick results
  • Quantitative measurements
  • Can be single analyte or multiplex
  • Data represents an average protein expression within sample

ELISA kits for Hypoxia Markers

Validated Antibody Pairs

Luminex Assays

Bio-Techne offers instruments to automate and streamline western blot and ELISA workflows:


Image of Abby Simple Western Instrument


Image of Ella automated immunoassay system.

View More Resources and Protocols for Hypoxia Detection



Image of immunohistochemistry and RNA in situ hybridization staining of monocyte marker CD11b. Small circular badge with horizontal bar graph indicating orthogonal strategies validation.

Simple Western. Mesenchymal stem cells (MSCs) media was changed in either a constant 3% O2 environment (left) or in room air (right) and levels of HIF1A were analyzed by simple western. Lysates were probed with Rabbit anti-HIF1A Monoclonal Antibody (2443C) (Catalog # NBP2-75978) and Goat Anti-Endoglin/CD105 Polyclonal Antibody (Catalog # AF1097). Data shows HIF1A protein expression changing substantially in room air environment compared to low oxygen environment, while CD105 a marker to delineate MSCs, remains constant. The specificity of NBP2-75978 and AF1097 have been validated by Genetic Strategies. NBP2-75978 specificity has also been validated by Biological Strategies.



While useful for preliminary screening, these whole cell lysate or subcellular fraction analyses present an average of total protein expression in the sample. Cells are exposed to various degrees of hypoxia depending on their location within the microenvironment and differential cellular responses would only be visible by a more nuanced, single-cell approach.


back to top



Single-Cell Detection of Hypoxia

Detection of hypoxia at the single-cell level can provide important information about the individual cellular response to hypoxia and how cells respond to the hypoxic gradient within cultures and tissues. In general, these techniques allow for more phenotypic information from one sample and show heterogeneity within cell cultures and tissue samples. Some common techniques to analyze hypoxia at single-cell level include flow cytometry, mass cytometry, ICC, IHC, ISH, and imaging cytometry.


Application

Advantages

Limitations

Bio-Techne Product Offering

Flow Cytometry and Mass Cytometry (CyTOF)

  • High throughput
  • Multiplex analysis
  • Simple cell number quantification
  • No spatial context
  • Limited quantification of protein expression

Antibodies for Flow Cytometry

Flow Cytometry Standardization Beads

CyTOF-ready Antibodies

IHC/ICC

  • Tissue (IHC) or subcellular (ICC) spatial context for hypoxia marker expression
  • Combine with gene expression (ISH) for multi-omic analysis
  • Quick results
  • Quantitative measurements
  • Can be single analyte or multiplex
  • Multiplexing requires specialized equipment and complex data analysis
  • Time consuming experiments and analysis
  • Limited quantification of protein expression

Hypoxia Marker Antibodies for IHC

Hypoxia Marker Antibodies for ICC

Secondary Antibodies

IHC Tissue Slides

IHC Tissue Microarrays

ISH

  • Provide spatial context for gene expression
  • Quantify gene expression
  • More reliable for proteins with short-half life, such as HIF-alpha proteins
  • Combine with protein expression (IHC) for multi-omic analysis.
  • Multiplexing requires specialized equipment and complex data analysis
  • RNA expression doesn’t always correlate with protein expression

RNAscope probes and RNAscope detection kits from ACD Biosciences

Antibodies validated for Dual RNAscope ISH-IHC



VEGF Expression in Human Angiosarcoma IHC

Immunohistochemistry (IHC)-Paraffin: IHC analysis of a formalin-fixed paraffin embedded human angiosarcoma tissue section using Mouse Anti-VEGF Monoclonal Antibody (VG1) (Catalog # NB100-664). The endothelial cells of the blood vessels and most of the cancer cells showed strong positivity for VEGF protein. The specificity of this antibody has been validated with Biological Strategies.


Additional techniques include imaging cytometry and imaging mass cytometry, combining the single-cell resolution and high throughput nature of conventional cytometry with the spatial data acquired with imaging techniques.


back to top



Hypoxia in 2D and 3D Culture Models

Hypoxia is common in tumors and occurs as the result of increased cell proliferation and metabolism, as well as deficiencies in blood supply and reduced tissue-oxygen diffusion. These factors continually expose tumor cells to fluctuating oxygenation which is difficult to replicate in the laboratory setting.

Tumor Oxygen Gradient and HIF-alpha Stability

View Hypoxic and Simulated-Hypoxic Cell Lysate Protocol

2D cell culture model systems have been predominantly used to study hypoxic responses. Most studies rely on culturing homogeneous cancer cell lines on flat surfaces that do not replicate the biologically significant extracellular environment.

Additional limitations of monolayer cell cultures include:

  • Cell-cell interactions are unlike those found in vivo
  • Cells acquire abnormal morphology
  • Cells have atypical distribution of membrane proteins

Various studies have shown that signaling pathways activated and resulting cellular adaptations that occur under hypoxia are influenced by the way cells are cultured in vitro. Therefore, 3D spheroid cell cultures have progressively become more accepted as model systems that more faithfully replicate the tumor microenvironment.

HIFs are stabilized in spheroids according to graded oxygen levels, similar to hypoxic tumor regions, reaching maximal expression in cells peripheral to the core. Several types of 3D spherical cultures have been developed that are reviewed in the white paper, A Technical Perspective: Understanding the Cellular Response to Hypoxia through In Vitro Model Systems


Modeling Hypoxia via Multicellular Tumor Spheroids


Learn More About Organoids and 3D Culture Models


back to top