E. coli-derived recombinant human SCF/c-kit Ligand (R&D Systems, Catalog # 255-SC) Glu26-Ala189 Accession # P21583
Specificity
Detects human SCF/c-kit Ligand in ELISAs and Western blots. In sandwich immunoassays, approximately 55% cross-reactivity with recombinant feline SCF is observed, 20% cross-reactivity with recombinant canine SCF is observed, and less than 0.3% cross-reactivity with recombinant mouse SCF is observed.
Source
N/A
Isotype
IgG
Clonality
Polyclonal
Host
Goat
Gene
KITLG
Purity Statement
Antigen Affinity-purified
Innovator's Reward
Test in a species/application not listed above to receive a full credit towards a future purchase.
Use a manual defrost freezer and avoid repeated freeze-thaw cycles.
12 months from date of receipt, -20 to -70 °C as supplied.
1 month, 2 to 8 °C under sterile conditions after reconstitution.
6 months, -20 to -70 °C under sterile conditions after reconstitution.
Buffer
Lyophilized from a 0.2 μm filtered solution in PBS with BSA as a carrier protein.
Preservative
No Preservative
Concentration
LYOPH
Reconstitution Instructions
Reconstitute at 0.2 mg/mL in sterile PBS.
Notes
This product is produced by and ships from R&D Systems, Inc., a Bio-Techne brand.
Alternate Names for SCF/c-kit Ligand Antibody [Biotin]
c-kit Ligand
DCUA
DFNA69
DKFZp686F2250
familial progressive hyperpigmentation 2
FPH2
FPHH
KIT ligand
Kitl
KITLG
KL-1
Mast cell growth factor
MGF
MGFSHEP7
SCF
SCFStem cell factor
SFc-Kit ligand
SHEP7
SLF
steel factor
Background
Stem cell factor (SCF), also known as c-kit ligand (KL), mast cell growth factor (MGF), and steel factor (SLF), is a widely expressed 28 - 40 kDa type I transmembrane glycoprotein (1). It promotes the survival, differentiation, and mobilization of multiple cell types including myeloid, erythroid, megakaryocytic, lymphoid, germ cell, and melanocyte progenitors (1-7). SCF is a primary growth and activation factor for mast cells and eosinophils (8). Mature human SCF consists of a 189 amino acid (aa) extracellular domain (ECD), a 23 aa transmembrane segment, and a 36 aa cytoplasmic tail (9). The ECD shows both N-linked and O-linked glycosylation (10). Proteolytic cleavage at two alternate sites in the extracellular juxtamembrane region releases a 25 kDa soluble molecule which is comparable to the only form produced by Steel-dickie mutant mice (11, 12). An alternately spliced isoform of human SCF lacks 28 aa that encompasses the primary proteolytic recognition site (13). Within the ECD of the short isoform (corresponding to this recombinant protein), human SCF shares 75%-83% aa sequence identity with canine, feline, mouse, and rat SCF. Rat SCF is active on mouse and human cells, but human SCF is only weakly active on mouse cells (9). Noncovalent dimers of transmembrane or soluble SCF interact with the receptor tyrosine kinase SCF R/c-kit to trigger receptor dimerization and signaling (14). SCF assists in the recovery of cardiac function following myocardial infarction by increasing the number of cardiomyocytes and vascular channels (15).
Ashman, L.K. (1999) Int. J. Biochem. Cell Biol. 31:1037.
Sette, C. et al. (2000) Int. J. Dev. Biol. 44:599.
Yoshida, H. et al. (2001) J. Invest. Dermatol. Symp. Proc. 6:1.
Erlandsson, A. et al. (2004) Exp. Cell Res. 301:201.
Kapur, R. et al. (2002) Blood 100:1287.
Wang, C-H. et al. (2007) Arterioscler. Thromb. Vasc. Biol. 27:540.
Bashamboo, A. et al. (2006) J. Cell Sci. 119:3039.
Reber, L. et al. (2006) Eur. J. Pharmacol. 533:327.
Martin, F.H. et al. (1990) Cell 63:203.
Arakawa, T. et al. (1991) J. Biol. Chem. 266:18942.
Majumdar, M.K. et al. (1994) J. Biol. Chem. 269:1237.
Brannan, C.I. et al. (1991) Proc. Natl. Acad. Sci. 88:4671.
Anderson, D.M. et al. (1991) Cell Growth Differ. 2:373.
Lemmon, M.A. et al. (1997) J. Biol. Chem. 272:6311.
Kanellakis, P. et al. (2006) Cardiovasc. Res. 70:117.
Limitations
This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.
The concentration calculator allows you to quickly calculate the volume, mass or concentration of your vial. Simply enter your mass, volume, or concentration values for your reagent and the calculator will determine the rest.
=
÷
Review this Product
Be the first to review our SCF/c-kit Ligand Antibody [Biotin] and receive a gift card or discount.