Lightning-Link antibody labeling kits enable the direct labeling of antibodies, proteins, peptides or other biomolecules for use in R&D applications, drug discovery and the development of diagnostic kits (See protocol for further information).
Our PE/Cy7 antibody labeling kit enables the direct conjugation of the PE/Cy7 tandem dye to any biomolecule with an available amine group. The researcher simply pipettes the antibody or other biomolecule into the vial of Lightning-Link label and incubates for 3 hours.
Features
Benefits
Quick and easy to use
Save time, no special knowledge required
No separation steps
100% recovery - no antibody/protein loss
Can be used in a wide range of applications
Flexible
Freeze dried
Ships at ambient temperature, long shelf-life
Fully scalable (10 ug to 1 g or more)
Easy transfer from R&D to manufacturing
Stringently QC tested
Consistent high quality, excellent batch-to-batch reproducibility
Large number of labels available
Experimental flexibility
Reliable: nearly 300 references
Successfully used in many fields of research
PE/Cy7 is a tandem conjugate. The PE has three maximal absorbance values of 498, 544 and 566nm with the optimal depending on the application. The PE functions as an energy donor for the Cy7. Energy is transferred from the PE to the Cy7 via energy resonance transfer. The Cy7 emits the energy received from the PE in the form of long wavelength light at 782nm.
Learn more about Lightning-Link™ Conjugation Kits by reading FAQs
By circumventing the desalting or dialysis steps that commonly interrupt traditional antibody conjugation procedures, LightningLink technology can be used to label both small (e.g. 10 ug) and large quantities of primary antibodies with ease. Batch-to-batch variation upon scale up is minimal as the process is so simple, and recoveries are always 100%. This kit can be used to label up to 600 ug of antibody, and is supplied in one vial.
This product is manufactured by Abcam and distributed by Novus Biologicals.
This product is for research use only and is not approved for use in humans or in clinical diagnosis. This product is guaranteed for 1 year from date of receipt and this statement overrides any mentioned guarantee period on the limitations section of this products datasheet. Please contact technical@novusbio.com with questions.
Background
Easy PE/Cy7 labeling of your antibody with 30 seconds hands-on time. PE/Cy7 is a tandem conjugate. The PE is excited at 488nm and functions as an energy donor for the Cy7. Energy is transferred from the PE to the Cy7 via energy resonance transfer. The Cy7 emits the energy received from the PE in the form of long wavelength light at 776nm.The Lightning-Link conjugation system represents a quantum leap forward in conjugation technology. It allows you to make antibody conjugates with minimal hands-on time less than 30 seconds. Lightning-Link simplifies immunoassay techniques, such as western blotting, ELISA and immunohistochemistry, by eliminating secondary reagents and cutting the number of incubation and wash steps.Despite its simplicity, Lightning-Link is a very sophisticated conjugation system in which the antibody is directionally coupled to the label (and not to itself) in a controlled fashion, creating high quality conjugates. As the procedure is not interrupted by desalting steps, trial conjugates can be prepared with microgram quantities of protein and then scaled up with ease. Lightning-Link eliminates problems associated with scale up; hands-on time is essentially independent of process scale. Consistency from batch to batch is easy to achieve, and recoveries approach 100%.
Limitations
This product is for research use only and is not approved for use in humans or in clinical diagnosis. Kits are guaranteed for 6 months from date of receipt.
Publications for Lightning-Link (R) PE-Cy7 Kit (762-0015)(10)
We have publications tested in 1 application: FLOW.
Reviews for Lightning-Link (R) PE-Cy7 Kit (762-0015) (0)
There are no reviews for Lightning-Link (R) PE-Cy7 Kit (762-0015).
By submitting a review you will receive an Amazon e-Gift Card or Novus Product Discount.
Review with no image -- $10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen
Review with an image -- $25/€18/£15/$25 CAD/¥150 Yuan/¥2500 Yen
Product General Protocols
Find general support by application which include: protocols, troubleshooting, illustrated assays, videos and webinars.
FAQs for Lightning-Link (R) PE-Cy7 Kit (762-0015). (Showing 1 - 9 of 9 FAQs).
Can I label a peptide/protein/antibody other than IgG?
Yes. The Lightning-Link® technology works by targeting free amine groups on your target, meaning it can be used to label most biomolecules.As the protocols provided were optimized for labeling IgGs, we would recommend you adjust the amount of material you add to the Lighting-Link® vial to allow for molecular weight difference. This should be done without changing the volume added to the vial, as this could affect the conjugation efficiency. As a rough guideline, we would recommend changing the amount of material proportionally to the size difference with IgGs. An average IgG is about 160kD, therefore for a target that is half the size of an antibody (about 80kD), add half as much to the vial. Please note this is only a guideline and the best amount for your assay should be determined experimentally; our 3x10ug kits enable you to do this using small amounts of material and therefore at a low cost.
Do I need a wash or desalt step?
One of the advantages of the Lightning-Link® technology compared to traditional labeling methods is that conjugate purification is not required. The Lightning-Link® reactions are highly efficient, and the kits have been optimized so that, provided the protocols are followed, there should be only a very low amount of free label left at the end of the conjugation. Any remaining free label would have its reactive 'Lightning-Link®' groups blocked by the Quencher provided in the kit, and would then be washed away during the relevant wash step of your application.
Do my antibody and buffer fit the requirements?
Your antibody should be purified (affinity purification is preferred), as other molecules with free amine groups will interfere with the reaction, resulting in a poor quality conjugate. A suitable method of purification should be used (such as affinity or Protein A/G). Please note that 0.2/0.22 um filtration is a method of sterilization, not purification.Your biomolecule should also be in a suitable, 10-50mM amine free buffer (e.g. MES, MOPS, HEPES, PBS), pH range 6.5 to 8.5 and not in any of the following: ascites fluid, serum or tissue culture supernatant. It should not contain any additives such as Azide, BSA, Tris or Glycine at a concentration of >0.1%.The amount of antibody (IgG) you should add to the Lightning-Link® vial usually corresponds to the kit size your purchased (for example: a 3x100ug kit enable you to label 3 lots of 100ug antibody) and the volume added should also match (eg: 100ul), meaning the ideal concentration is of 1mg/ml. For other biomolecule, the amount added should be adjusted by changing your concentration (see above).NOTE: The amount and volume of antibody recommended above are for all Lightning-Link• kits offered by Innova Biosciences, with the exception of RPE and PE tandem dyes. For more details on the recommendations specific to these dyes, please consult the protocols available on each product page.
How many labels will bind to my biomolecule?
It is difficult to give a precise answer to this as the result will vary from antibody to antibody (or other protein). Traditional labelling techniques often have F/P ratios in the range of 4-7:1, and our comparative data for staining with antibodies labelled with Lightning Link shows similar staining intensity. The ratio of dye to antibody is only ever an average for the population of labelled molecules, as individual molecules may have different amount of dye incorporated into them.
How stable will my new conjugate be?
The Lightning-Link® chemistry joins the label to the antibody via a uni directional stable, covalent bond. The stability of your conjugate will therefore be dependent on your antibody and label of choice. In our in-house studies, conjugates made with our Lightning-Link® kits were fully active after more than 18 months' storage, undiluted, at 4 degrees C. Conjugates stored in 50% glycerol at -20 degrees C were found to be even more stable (several years). Please see below for advice on storage conditions. Please note that tandem dye stability is lower than the other dyes'. Tandem conjugates are fully stable for about 3 months at 4 degrees C.
What are the best storage conditions for my new conjugate?
TA new conjugate can be stored for 12-18 months at 4 degrees C as long as the antibody will tolerate storage at 4 degrees C. As the bond between the antibody and dye is covalent and very stable, it should not degrade, therefore at 4 degrees C no additional preservatives are needed. The antibody is usually the least stable component of the conjugate so please check the antibody datasheet for storage recommendations. However, all conjugates can be stored in 50% glycerol at -20 degrees C which allows them to remain stable for 2 years. Please bear in mind that APC and RPE conjugates should never be stored at -20 degrees C on their own without glycerol. The dilution factor also has an effect. Storing the conjugate undiluted is recommended if possible; however, for HRP conjugates, if you wish to store at working concentrations (e.g. 1/10,000), this can be done using our LifeXtend HRP Conjugate Stabilizer/Diluent. Please note that the preservative sodium azide will inhibit HRP. We suggest that the optimal storage conditions for any conjugate are determined experimentally, using small aliquots of the conjugate.
What can I do if my antibody formulation does not fit the requirements?
If your antibody buffer is not compatible with our kits, we have developed an AbSelect™ purification kit range that allows you to quickly and simply purify your antibody and is fully compatible with the Lightning-Link® kits.The appropriate kit to use depends on your particular sample (species, buffer, contaminants, volume,...). We have designed a handy flow chart on the AbSelect™ webpage to help you select a kit, but feel free to contact us if you require further guidance. Please consult the kit protocols to see the antibody amount/volume suitable for each kit.If your antibody is already purified but its concentration is too low, you can concentrate it by using our Antibody Concentration and Clean Up Kit. This kit can also be used to remove low molecular weight contaminants such as azide, tris or glycine by carrying out a buffer exchange into the buffer supplied in the kit, which is fully compatible with Lightning-Link®.If your antibody contains BSA, you can now use our BSA removal kit to purify your antibody in a few simple steps. Please note this kit will also enable you to concentrate your antibody.NB: All the AbSelect kits will ONLY work with antibodies. They will not purify other molecules. The only exception is the concentration and clean up kit (861-0010), which will work with other molecules greater than 10kD.
What is the difference between Lightning-Link® and Lightning-Link® Rapid?
The benefit of the Rapid kits is that the conjugates can be generated faster because the conjugation and quenching incubation times are shorter. The antibody/protein/peptide considerations are exactly the same, as is the high quality of the final conjugate. DyLight® dyes are only available in the Rapid format.
I want to conjugate an antibody with PE-CY7 that would be used for intracellular staining. Can this kit be used for intracellular staining? The antibody to be conjugated is LKLF
The Lightning-Link PE-Cy7 Kit (762-0015) can be used to label your antibody for use in the application of your choice (assuming your antibody has been validated in such application). This labeling kit should perform just fine for your experiment. If you choose to use this kit to label your antibody, you will want to be sure that your antibody is purified because this kit labels free amines and other molecules can be labeled if the antibody is unpurified.